As the professional manufacture, we would like to provide you Single-Phase Latching Relay.
● 120A contact load capability ● IEC 62052-31 UC3 standard compliant ● Contact gap ≥ 5.5 mm■ 120A single-phase latching relay.
■ Meet the standard of lEC62055-31 UC3 .
■ Contact gap≥5.5mm.
■ Used for smart meters, electrical remote control, electrical load switches, and electrical equipment.
1 Part number NFE106
2 Contact arrangement
SA: A set of normally open double contacts
SB: A set of normally closed double contacts
3 Contact current : 120A4 Coil rated voltage(V) : DC:12
|
Contact Arrangement |
SA SB |
|
Contact Material |
AgSnO₂ |
|
Contact Rating |
120A 220VAC |
|
Max. Switching Power |
26400VA |
|
Max. Switching Voltage |
220VAC |
|
Max. Switching Current |
120A |
|
Contact Resistance |
≤0.5mΩ (at 120A) |
|
Electrical Endurance |
1000 |
|
Mechanical Endurance |
7000 |
Notes:
1. SA indicates that the relay contacts are in the open state upon factory delivery; SB indicates that the relay contacts are in the closed state upon factory delivery. Unless otherwise specified by the customer, our company will default to shipping the relay with its contacts closed.
2. UC3: The product conforms to clause of GB/T 17215.231 2021: making capacity: 3kA/10ms, withstand capacity: 6kA/10ms.
|
Coil voltage VDC |
Coil resistance Ω ±10% |
Set/Reset voltage VDC (≤70% of rated voltage) |
Pulse duration ms |
Coil power W |
Set time ms |
Reset time ms |
|
12 |
12 |
8.4 |
150 |
12 |
≤ 30 |
≤ 30 |
Notes:
1. When latching relays are installed in equipment, coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to be in the magnetically neutral position.
2. Do not apply voltage to the coil for a long period (more than 1 minute).
|
Insulation Resistance |
1000MΩ (500VDC) |
|
Dielectric Strength |
2000VAC 1min |
|
Shock resistance |
Functional: 98m/s² 11ms; Destructive: 980m/s² 11ms |
|
Vibration resistance |
10Hz~55Hz Double amplitude 1.5mm |
|
Ambient Temperature |
-40℃ ~ 70℃ |
|
Relative Humidity |
5%~85% |
|
Temperature Rise (rated load) |
≤55K |
|
Enclosure |
Dust cover |
Remark :
1.Latching relays leave the factory with the contacts in the closed (reset) position. However, shocks during shipping or installation can alter this state. Thus, prior to use (upon power-up), it is necessary to take action to reset the relay.
2.Normally the load terminals are not suitable for reflow solder, wave solder or tin solder, we suggest use spot welding. Load terminals shall be prevented from mounting stress, or freely move .
3.Relays used for metering measuring applications are usually made with dust proof structure, while most relays could be made specially per customer's specific requirements. No longer than 6 months storage time is recommended for this kind of relay, and please pay attention to the storage environment.