As a professional high quality 10A Polarized Latching Relay manufacture, you can rest assured to buy 10A Polarized Latching Relay from our factory and we will offer you the best after-sale service and timely delivery.
● 10A switching capability ● High insulation ● Small size and light weight ● RoHS CompliantAs the professional manufacture, we would like to provide you 10A Polarized Latching Relay. Due to our focused approach, timely delivery and ethical business policy, we have been able to gain tremendous success in this domain.
Latching relay.
Small size and light weight.
Contact switching capacity can reach 10A.
PC board mounting.
1 Part number: NT74L
2 Contact arrangement: A:1A; C:1C
3 Enclosure: S: Wash tight Z: Flux proof
4 Coil rated voltage(V): DC:3,5,12,24
5 Coil NIL:Single coil D: double coils
6 Polarity Nil: standard R: reverse polarity
7 Contact plating NIL:Standard G:Gold plated
Contact Arrangement | 1A(SPSTNO) 1C(SPDT(B-M)) | |||
Contact Material | AgSnO2 | |||
Contact Rating (Resistive) |
NO:10A/250VAC,24VDC NC:8A/250VAC,24VDC |
|||
Max. Switching Power | 240W 2500VA | |||
Max. Switching Voltage | 150VDC 400VAC | Max. Switching Current :10A | ||
Contact Resistance | ≤100mΩ | Item 4.12 of IEC 61810-7 | ||
Operation | Electrical | 5×104 | Item 4.30 of IEC 61810-7 | |
Life | Mechanical | 5×106 | Item 4.31 of IEC 61810-7 |
Dash numbers | Rated voltage VDC |
Coil resistance Ω±10% |
Set/Reset voltage VDC (70% of rated voltage ) |
Pulse duration ms | Coil power W | Set time ms | Reset time ms |
1 Coil | |||||||
003-250 | 3 | 36 | 2.1 | ≥30 | 0.25 | ≤10 | ≤10 |
005-250 | 8 | 100 | 3.5 | ||||
012-250 | 12 | 576 | 8.4 | ||||
024-250 | 24 | 2300 | 16.8 | ||||
2 Coils | |||||||
003-480 | 3 | 2×19 | 2.1 | ≥30 | 2×0.48 | ≤10 | ≤10 |
005-480 | 5 | 2×52 | 3.5 | ||||
012-480 | 12 | 2×300 | 8.4 | ||||
024-480 | 24 | 2×1200 | 16.8 |
CAUTION:
1. When latching relays are installed in equipment, the latch and reset coil should not be powered simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to in be the magnetically neutral position .
2. Switching voltage is for test purpose only and are no to be used as design criteria.
Insulation Resistance | 100MΩ min (at 500VDC) | Item 4.11 of IEC 61810-7 |
Dielectric Strength |
|
|
Between Contacts | 50Hz 1000VAC | Item 4.9 of IEC 61810-7 |
Between Contact and Coil | 50Hz 5000VAC | Item 4.9 of IEC 61810-7 |
Shock Resistance | Functional: 98m/s² | Item 4.26 of IEC 61810-7 |
Destructive: 980m/s² | ||
Vibration Resistance | 10Hz~55Hz Double amplitude 1.65mm | Item 4.28 of IEC 61810-7 |
Terminals Strength | 10N | Item 4.24 of IEC 61810-7 |
Ambient Temperature | -40℃~85℃ | |
Relative Humidity | 5% to 85% | Item 4.16 of IEC 61810-7 |
Mass | 8g | Item 4.7 of IEC 61810-7 |
CAUTION
In case of no tolerance shown in outline dimension: outline dimension ≤1mm tolerance should be ±0.2mm outline dimension >1mm and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
Address
NO.11, 125 Lane, Qi-Wen Road, Haishu District, Ningbo, Zhejiang, China, 315012