As the professional manufacture, we would like to provide you high quality 50A Miniature High Power Latching Relay. And we will offer you the best after-sale service and timely delivery. Our products have a good quality&price advantage and cover most of the European and American markets. We look forward to becoming your long-term partner in China.
● 50A switching capability ● Single coil and dual coil available ● Energy Saving ● Environmental friendly productAs a professional high quality 50A Miniature High Power Latching Relay manufacture, you can rest assured to buy Subminiature PCB Power Relay 5A from our factory and we will offer you the best after-sale service and timely delivery. We hope to establish friendly cooperative relationship with your company with high quality products, reasonable price, considerate service and create a better future hand in hand.
Single and double coils magnet latching relay available.
Switching capacity up to 50A.
PC board mounting.
1 Part number: NT95L
2 Contact arrangement: A:1A C:1C
3 Coil: NIL:Single coil; D: Double coils
4 Enclosure: Z: Flux proof(With manual switch) S:Wash tight(Without manual switch)
5 Polarity Nil: standard; R: reverse polarity
6 Coil rated voltage(V): DC:6,9,12,24,48
| Dash numbers | Rated voltage VDC |
Coil resistance Ω±10% |
Set/Reset voltage VDC (80% of rated voltage ) |
Pulse duration ms | Coil power W | Set time ms | Reset time ms |
| 1 Coil | |||||||
| 006-1500 | 6 | 24 | 4.8 | ≥50 | 1.5 | ≤15 | ≤15 |
| 009-1500 | 9 | 54 | 7.2 | ||||
| 012-1500 | 12 | 96 | 9.6 | ||||
| 024-1500 | 24 | 384 | 19.2 | ||||
| 048-1500 | 48 | 1536 | 38.4 | ||||
| 2 Coils | |||||||
| 006-3000 | 6 | 2×12 | 4.8 | ≥50 | 2×3.0 | ≤15 | ≤15 |
| 009-3000 | 9 | 2×27 | 7.2 | ||||
| 012-3000 | 12 | 2×48 | 9.6 | ||||
| 024-3000 | 24 | 2×192 | 19.2 | ||||
| 048-3000 | 48 | 2×768 | 38.4 | ||||
CAUTION:
1. When latching relays are installed in equipment, the latch and reset coil should not be powered simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to in be the magnetically neutral position .
2. Switching voltage is for test purpose only and are no to be used as design criteria.
| Insulation Resistance | 1000MΩ min (at 500VDC) | Item 4.11 of IEC 61810-7 |
| Dielectric Strength |
|
|
| Between Contacts | 50Hz 1500VAC | Item 4.9 of IEC 61810-7 |
| Between Contact and Coil | 50Hz 4000V | Item 4.9 of IEC 61810-7 |
| Creepage Distance | 1A:8mm 1C:6mm | |
| Shock Resistance | Functional: 98m/s² 11ms | Item 4.26 of IEC 61810-7 |
| Destructive: 980m/s² 11ms | ||
| Vibration Resistance | 10Hz~55Hz Double amplitude 1.5mm | Item 4.28 of IEC 61810-7 |
| Terminals Strength | 10N | Item 4.24 of IEC 61810-7 |
| Ambient Temperature | -40℃~70℃ | |
| Relative Humidity | 5% to 85% | Item 4.16 of IEC 61810-7 |
| Mass |
1A:25g; 1C:29g |
Item 4.7 of IEC 61810-7 |
| Safety approval | UL&CUR | CQC |
| Load | 1A:50A/277VAC | 1A:50A/277VAC |
Address
NO.11, 125 Lane, Qi-Wen Road, Haishu District, Ningbo, Zhejiang, China, 315012