You can rest assured to buy 60A Miniature High Power Relay With Big Gap from our factory and we will offer you the best after-sale service and timely delivery.
● 60A switching capability ● Contact gap ≥ 1.8mm ● Strong anti-shock, anti-vibration and high reliability ● Product in accordance to IEC60335-1 available ● RoHS CompliantAs a professional high quality 60A Miniature High Power Relay With Big Gap manufacture, you can rest assured to buy 50A Miniature High Power Relay With Big Gap from our factory and we will offer you the best after-sale service and timely delivery.
50A/60A switching capability.
Contact gap: 1.8mm.
Ideal for charger.
Applicable to inverter used for photovoltaic power generation systems.
Product in accordance to IEC 60335-1 available
1 Part number: NT90W
2 Load: 50:50A 60:60A
3 Contact arrangement: A:1A C:1C
4 Enclosure: S: Wash tight E: Flux proof
5 Coil rated voltage(V): DC:5,6,9,12,15,18,24,48 6 Contact material S: AgSnO2
7 Contact gap: S:1.8mm; Nil: Standard gap
8 Coil power: Nill:2.25W; L:1.2W
9 W:335 compliant Nil:Standard
Contact Power | 1.2W | 2.25W | |
Contact Arrangement | 1A SPSTNO) 1C(SPDT(B-M)) | 1A(SPSTNO) | |
Contact Material | AgSnO2 | AgSnO2 | |
Contact Rating(Resistive) |
NO:50A,60A/277VAC |
50A/277VAC 35A/277VAC(S Gap) 40A/30VDC |
|
Max. Switching Power | 14400VA | 1200W 13850VA | |
Max. Switching Voltage | 280VAC | 1200W 13850VA | |
Max. Switching Current | 60A | ||
Contact Resistance | ≤30mΩ | Item 4.12 of IEC61810-7 | |
Operational Life | Electrical |
1×104 (NO:60A/277VAC,Resistive load, 65℃, 1s on 9s off) 2×104 (NO:50A/277VAC,Resistive load, 65℃, 1s on 9s off) 1×104 (NC:35A/277VAC,Resistive load, 65℃, 1s on 9s off) 3×104 (S Gap)(35A/277VAC,Resistive load, 85℃, 1s on 9s off) |
Item 4.30 of IEC 61810 -7 |
Mechanical | 1×106 | Item 4.31 of IEC 61810-7 |
Dash numbers | Rated voltage VDC |
Coil resistance Ω±10% |
Pick-up voltage V(max) (75% of rated voltage) | Drop-out voltage V(min) (10%of rated voltage) | Coil power W | Operate time ms | Release time ms | |
Rated | Max | |||||||
005-1200 | 5 | 6.5 | 20.8 | 3.75 | 0.5 | 1.2 | ≤15 | ≤10 |
006-1200 | 6 | 7.8 | 30 | 4.50 | 0.6 | |||
009-1200 | 9 | 11.7 | 67.5 | 6.75 | 0.9 | |||
012-1200 | 12 | 15.6 | 120 | 9.00 | 1.2 | |||
015-1200 | 15 | 19.5 | 187.5 | 10.25 | 1.5 | |||
018-1200 | 18 | 23.4 | 270 | 13.50 | 1.8 | |||
024-1200 | 24 | 31.2 | 480 | 18.00 | 2.4 | |||
048-1200 | 48 | 62.4 | 1920 | 36.00 | 4.8 | |||
012-2250 | 12 | 15.6 | 64 | 9.00 | 1.2 | 2.25 | ≤15 | ≤10 |
024-2250 | 24 | 31.2 | 256 | 18.00 | 2.4 |
After the energization time of 100 ms with rated voltage, the coil voltage can be reduced to 40%~50% of the rated voltage.
Insulation Resistance | 1000MΩ min (at 500VDC) | Item 4.11 of IEC 61810-7 |
Dielectric Strength |
|
|
Between Contacts |
50Hz 1500V 2500V(S Gap) |
Item 4.9 of IEC 61810-7 |
Between Contact and Coil |
50Hz 2500V 4000V* |
Item 4.9 of IEC 61810-7 |
Shock Resistance | Functional: 98m/s² | Item 4.26 of IEC 61810-7 |
Destructive: 980m/s² | ||
Vibration Resistance |
10Hz~55Hz Double amplitude 1.5mm |
Item 4.28 of IEC 61810-7 |
Terminals Strength | 10N | Item 4.24 of IEC 61810-7 |
Surge Voltage (Between Coil & Contacts) |
6kV(1.2/50 μs) | Item 4.10 of IEC 61810-7 |
Ambient Temperature | -55℃~85℃ | |
Relative Humidity | 5% to 85% | Item 4.16 of IEC 61810-7 |
Mass | 27g | Item 4.7 of IEC 61810-7 |
* Please contact the sales representative if 4000V is required.
Safety approval | UL&CUR | TüV | CQC |
Load |
50A/277VAC 40℃ 35A/277VAC 85℃ |
35A,40A,50A/277VAC 35A,40A,50A/250VAC |
50A/277VAC 40A/277VAC,250VAC 35A/277VAC,250VAC |
CAUTION
In case of no tolerance shown in outline dimension: outline dimension ≤1mm tolerance should be ±0.2mm outline dimension >1mm and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
Address
NO.11, 125 Lane, Qi-Wen Road, Haishu District, Ningbo, Zhejiang, China, 315012
Tel
TradeManager
Skype
VKontakte