● 40A switching capability
● Low coil power consumption
● Heavy contact load
● Strong anti-shock, anti-vibration and high reliability
● Plastic sealed and flux proofed types available
● RoHS Compliant

Model:NT90T

Send Inquiry    PDF DownLoad

Product Description

As the professional manufacture, we would like to provide you Miniature High Power Relay For Quick-connect and PCB Terminals. We do everything we can to add value to our customers' experiences, allowing us to be their best option.

Features

Small size, light weight.

Low coil power consumption, heavy contact load.

Strong anti-shock and anti-vibration, high reliability, long life.

Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications.

PC board mounting and direct insert mounting available.


Ordering Information

1 Part number: NT90T NT90T2

2 Load: H:30A N:40A

3 High: NIL: Standard L: Low profile type

4 Contact arrangement: A:1A B:1B C:1C

5 Enclosure: S: Wash tight; D: Dust protected; E: Flux proof

6 Coil rated voltage(V): AC:12,24,110,120,220,240,277; DC:3,5,6,9,12,15,18,24,48,110

7 Contact material: S: AgSnO2 C:AgCdO

8 Resist heat class: B:130℃ F:155℃

9 Coil power: 0.6:0.6W; 0.9:0.9W; 2:2VA


Contact Data

Contact Arrangement 1A(SPSTBNO) 1B(SPSTNC) 1C(SPDT(B-M))
Contact Material AgSnO2 AgCdO
Contact Rating(Resistive)

NO:30A/240VAC,14VDC; NC:20A/240VAC;30A/14VDC
NO:40A/240VAC,30VDC; NC:30A/240VAC,30VDC (0.9W)
NO:30A/277VAC;NC:20A/277VAC
Motor Load NO:2HP 250VAC NC:1.5HP 250VAC
TV-5 5A/280VAC(Ballast)

Max. Switching Power 1200W 7200VA (10000VA)
Max. Switching Voltage 30VDC  280VAC Max. Switching Current: 40A
Contact Resistance ≤30mΩ Item 4.12 of IEC61810-7
Operational Life Electrical 1×105
Item 4.30 of IEC 61810 -7
Mechanical 1×107 Item 4.31 of IEC 61810-7


Coil Parameter

AC Coil Parameter
Dash numbers Rated voltage V Rated current mA Coil resistance
Ω±10%
Pick-up voltage VAC(max) (75%of rated voltage) Drop-out voltage VAC(min) (30%of rated voltage) Coil power VA Operate time ms Release time ms
Rated Max
012AC 12 15.6 166.6 27 9.0 3.6 2VA ___ ___
024AC 24 31.2 83.3 120 18.0 7.2
110AC 110 143 18.1 2360 82.5 33.0
120AC 120 156 16.6 3040 90.0 36.0
220AC 220 286 9.1 13490 165.0 66.0
240AC 240 312 8.3 15740 180 72
277AC 277 360.1 7.2 20300 207.8 83.1

CAUTION:

1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.

2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.


Coil Parameter

DC Coil Parameter
Dash numbers Coil voltage V Coil resistance
Ω±10%
Pick-up voltage VDC(max) (75% of rated voltage) Drop-out voltage VDC(min) (10% of rated voltage) Coil power W Operate time ms Release time ms
Rated Max.
003-900 3 3.9 10 2.25 0.3 0.9 ≤15 ≤10
005-900 5 6.5 28 3.75 0.5
006-900 6 7.8 40 4.50 0.6
009-900 9 11.7 90 6.75 0.9
012-900
12
15.6
160
9.00
1.2
015-900 15 19.5 250 10.25 1.5
018-900 18 23.4 360 13.50 1.8
024-900 24 31.2 640 18.00 2.4
048-900 48 62.4 2560 36.00 4.8
110-900 110 143 13445 82.50 11.0
003-600 3 3.9 15 2.25 0.3 0.6 ≤15 ≤10
005-600 5 6.5 42 3.75 0.5
006-600 6 7.8 60 4.50 0.6
009-600 9 11.7 135 6.75 0.9
012-600 12 15.6 240 9.00 1.2
015-600 15 19.5 375 10.25 1.5
018-600 18 23.4 540 13.50 1.8
024-600 24 31.2 960 18.00 2.4
048-600 48 62.4 3840 36.00 4.8
110-600 110 143 20167 82.50 11.0

CAUTION:

1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.

2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.


Characteristics

Insulation Resistance 1000MΩ min (at 500VDC) Item 4.11 of IEC 61810-7
Dielectric Strength

Between Contacts

50Hz 1500V

Item 4.9   of IEC 61810-7
Between Contact and Coil 50Hz 2500V
Item 4.9   of IEC 61810-7
Shock Resistance Functional: 98m/s²                            11ms Item 4.26 of IEC 61810-7
Destructive: 980m/s²                            11ms
Vibration Resistance 10Hz~55Hz Double amplitude 1.5mm
Item 4.28 of IEC 61810-7
Terminals Strength 10N Item 4.24 of IEC 61810-7
Ambient Temperature -55℃~85℃
Relative Humidity 5% to 85% Item 4.16 of IEC 61810-7
Mass 31g   Low Profile Type 35g Item 4.7 of IEC 61810-7