As the professional manufacture, we would like to provide you high quality Miniature High Power Relay With Flanged Mounting. And we will offer you the best after-sale service and timely delivery. Our product has been well accepted more than 20 countries, like USA, Canada, UK, Australia etc countries.
● 40A switching capability ● QC terminals ● Low coil power consumption ● Heavy contact load ● Strong anti-shock, anti-vibration and high reliability ● RoHS CompliantAs a professional high quality Miniature High Power Relay With Flanged Mounting manufacture, you can rest assured to buy Miniature High Power Relay With Flanged Mounting from our factory and we will offer you the best after-sale service and timely delivery. Our focus is on maintaining a high level of professionalism, service, and quality.
Small size, light weight.
Low coil power consumption, heavy contact load.
Strong anti-shock and anti-vibration, high reliability, long life.
Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications.
1 Part number: NT90TP, NT90TP2
2 Load: H:30A N:40A
3 High: NIL: Standard L: Low profile type
4 Contact arrangement: A:1A B:1B C:1C
5 Enclosure: D: Dust protected E: Flux proof
6 Coil rated Voltage(V:) AC:12,24, 110,120,220,240,277; DC:3,5,6,9,12,15,18,24,36,48,110
7 Contact material: S:AgSnO2 C: AgCdO
8 Resist heat class: B:130 F:155
9 Coil power: 0.6:0.6W 0.9:0.9W 2:2VA
Contact Arrangement | 1A(SPSTNO) 1B(SPSTNC) 1C(SPDT(B-M)) | ||
Contact Material | AgSnO2AgCdO | ||
Contact Rating(Resistive) | NO:30A/240VAC,14VDC; NC:20A/240VAC;30A/14VDC | ||
NO:40A/240VAC,30VDC; NC:30A/240VAC,30VDC (0.9W) | |||
NO:30A/277VAC;NC:20A/277VAC | |||
Motor Load NO:2HP 250VAC NC:1.5HP 250VAC | |||
TV-5 5A/280VAC(Ballast) | |||
Max. Switching Power | 1200W 7200VA (10000VA) | ||
Max. Switching Voltage | 30VDC 280VAC | Max. Switching Current:40A | |
Contact Resistance | ≤30mΩ | Item 4.12 of IEC 61810-7 | |
Operation Life |
Electrical | 1×105 | Item 4.30 of IEC 61810-7 |
Mechanical | 1×107 | Item 4.31 of IEC 61810-7 |
AC Coil Parameter | |||||||||
Dash numbers | Coil voltage VDC |
Rated current mA |
Coil resistance Ω±10% |
Pick-up voltage VDC(max) (75% of rated voltage ) | Drop-out voltage VDC(min) (30% of rated voltage) | Coil power VA | Operate time ms | Release time ms | |
Rated | Max. | ||||||||
012AC |
12 |
15.6 |
166.6 |
27 |
9.0 | 3.6 | 2VA | ____ | ____ |
024AC |
24 |
31.2 |
83.3 |
120 |
18.0 | 7.2 | |||
110AC |
110 |
143 |
18.1 |
2360 |
82.5 | 33.0 | |||
120AC |
120 |
156 |
16.6 |
3040 |
90.0 | 36.0 | |||
220AC |
220 |
286 |
9.1 |
13490 |
165.0 | 66.0 | |||
240AC |
240 |
312 |
8.3 |
15740 |
180 | 72 | |||
277AC |
277 |
360.1 |
7.2 |
20300 |
207.8 | 83.1 |
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
DC Coil Parameter | |||||||||
Dash numbers | Coil voltage V |
Coil resistance Ω±10% |
Pick-up voltage VDC(max) (75% of rated voltage ) | Drop-out voltage VDC(min) (10% of rated voltage) | Coil power W | Operate time ms | Release time ms | ||
Rated | Max. | ||||||||
003-900 |
3 |
3.9 |
10 |
2.25 |
0.3 | 0.9 | ≤15 | ≤10 | |
005-900 |
5 |
6.5 |
28 |
3.75 |
0.5 | ||||
006-900 |
6 |
7.8 |
40 |
4.50 |
0.6 | ||||
009-900 |
9 |
11.7 |
90 |
6.75 |
0.9 | ||||
012-900 |
12 |
15.6 |
160 |
9.00 |
1.2 | ||||
015-900 |
15 |
19.5 |
250 |
10.25 |
1.5 | ||||
018-900 |
18 |
23.4 |
360 |
13.50 |
1.8 | ||||
024-900 |
24 |
31.2 |
640 |
18.00 |
2.4 | ||||
036-900 |
36 |
46.8 |
1440 |
27.00 |
3.6 | ||||
048-900 |
48 |
62.4 |
2560 |
36.00 |
4.8 | ||||
110-900 |
110 |
143 |
13445 |
82.50 |
11.0 | ||||
003-600 |
3 |
3.9 |
15 |
2.25 |
0.3 | 0.6 | ≤15 | ≤10 | |
005-600 |
5 |
6.5 |
42 |
3.75 |
0.5 | ||||
006-600 |
6 |
7.8 |
60 |
4.50 |
0.6 | ||||
009-600 |
9 |
11.7 |
135 |
6.75 |
0.9 | ||||
012-600 |
12 |
15.6 |
240 |
9.00 |
1.2 | ||||
015-600 |
15 |
19.5 |
375 |
10.25 |
1.5 | ||||
018-600 |
18 |
23.4 |
540 |
13.50 |
1.8 | ||||
024-600 |
24 |
31.2 |
960 |
18.00 |
2.4 | ||||
048-600 |
48 |
62.4 |
3840 |
36.00 |
4.8 | ||||
110-600 |
110 |
143 |
20167 |
82.50 |
11.0 |
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Insulation Resistance | 1000MΩ min (at 500VDC) | Item 4.11 of IEC 61810-7 |
Dielectric Strength Between Contacts Between Contact and Coil |
50Hz 1500V 50Hz 2500V |
Item 4.9 of IEC 61810-7 Item 4.9 of IEC 61810-7 |
Shock Resistance | Functional: 98m/s² 11ms | tem 4.26 of IEC 61810-7 |
Destructive: 980m/s² 11ms | tem 4.26 of IEC 61810-7 | |
Vibration Resistance | 10Hz~55Hz Double amplitude 1.5mm | Item 4.28 of IEC 61810-7 |
Terminals Strength | 10N | Item 4.24 of IEC 61810-7 |
Ambient Temperature | -55℃~85℃ | |
Relative Humidity | 5% to 85% | Item 4.16 of IEC 61810-7 |
Mass | 35g (Low profile type) 37g | Item 4.7 of IEC 61810-7 |
Safety approval | UL&CUR | TüV | CQC |
Load |
NO:40A/240VAC ;30A/277VAC NC:30A/240VAC,30VDC;20A/277VAC Ballast:5A/280VAC TV-5 NO:2 HP 250VAC A:1HP/16AFLA/120VAC 2HP/12AFLA/240VAC NC:1 HP 250VAC B:30LRA/10AFLA/120VAC 30LRA/10AFLA/240VAC |
NO:40A/240VAC, 14VDC 30A/277VAC NC:30A/240VAC ,14VDC 20A/277VAC |
NO:40A/240VAC 30A/240VAC NC:30A/240VAC 20A/240VAC |
CAUTION
In case of no tolerance shown in outline dimension: outline dimension ≤1mm tolerance should be ±0.2mm outline dimension >1mm and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.