As the professional manufacture, we would like to provide you General Purpose Relay for Heavy Power Switching. We hope to establish friendly cooperative relationship with your company with high quality products, reasonable price, considerate service and create a better future hand in hand.
● Optional mounting ways ● Max Switching Current 2- Pole, 3- Pole :10A, 4- Pole : 5A ● Push to test button , built-in diode and LED indicator available ● Strong anti-shock, anti-vibration and high reliability ● RoHS CompliantAs the professional manufacture, we would like to provide you high quality General Purpose Relay for Heavy Power Switching. We firmly believe that perseverance is the key to the success of an enterprise. Continuous satisfaction of the needs of consumers is the basis for the survival of an enterprise, and products quality is the life of an enterprise.
Small size, light weight, heavy reverse power.
Optional mounting ways.
Firm structure, strong anti-shock & anti vibration.
Suitable for automatic control, telecommunication equipment, household electrical appliances and machinery electrical facilities.
1 Part number: JZX-18FF
2 Contact arrangement: 2C:2C; 3C:3C; 4C:4C
3 Terminal: a: inserting type; b: PCB type
4 Coil rated Voltage(V): AC:6,12,24,36,48,110,120,220; DC:6,12,24,36,48,110
5 Cover: 1:1Mode; 2:2 Mode
6 Coil transient suppression: L:with LED
D:with diode
LD:with LED & diode
NIL:standard
Contact Arrangement | 2C (DPDT (B-M); 3C (3PDT (B-M); 4C (4PDT(B-M)) | ||
Contact Material | AgCdO Ag Alloy | ||
Contact Rating (Resistive) | 2C&3C:5A,7A/220VAC,28VDC; 7A/250VAC Heavy Load:10A/220VAC,28VDC4C:3A/220VAC,28VDC; Heavy Load:5A/220VAC,28VDC | ||
Max. Switching Power | 280W 2500VA | ||
Max. Switching Voltage | 150VDC 300VAC | Max. Switching Current:20A | |
Contact Resistance | ≤50mΩ | Item 4.12 of IEC 61810-7 | |
Operation Life | Electrical | 3A:5×105; 5A:2×105, 7A,10A: 1×105 | Item 4.30 of IEC 61810-7 |
Mechanical | 2×107 Heavy load: 1×107 | Item 4.31 of IEC 61810-7 |
Dash numbers | Coil voltage V |
Coil resistance Ω±10% |
Rated current mA | Pick-up voltage V(max) (80% of rated Voltage) | Drop-out voltage V(min) (10% of rated voltage) | Coil power | Operate time ms | Release time ms | |
Rated | Max. | ||||||||
006-900 | 6 | 6.6 | 40 | 150 | 4.8 | 0.6 | 0.9W | ≤25 | ≤25 |
012-900 | 12 | 13.2 | 160 | 75 | 9.6 | 1.2 | |||
024-900 |
24 |
26.4 |
640/650 |
36.9 |
19.2 |
2.4 | |||
036-900 | 36 | 39.6 | 1500 | 24.5 | 28.8 | 3.6 | |||
048-900 | 48 | 52.8 | 2600 | 18.5 | 38.4 | 4.8 | |||
110-900 | 110 | 121 | 11000 | 10.0 | 88.0 | 11.0 |
Dash numbers | Coil voltage V |
Coil resistance Ω±10% |
Rated current mA | Pick-up voltage V(max) (80% of rated Voltage) | Drop-out voltage V(min) (30% of rated voltage) | Coil power | Operate time ms | Release time ms | |
Rated | Max. | ||||||||
006AC-1200 | 6 | 6.6 | 11.5 | 183.0 | 4.8 | 1.8 | 1.2VA | ≤25 | ≤25 |
012AC-1200 | 12 | 13.2 | 46 | 91.0 | 9.6 | 3.6 | |||
024AC-1200 | 24 | 26.4 | 184 | 46.0 | 19.2 | 7.2 | |||
036AC-1200 |
36 |
39.6 |
370 |
33.0 |
28.8 |
10.8 | |||
048AC-1200 | 48 | 52.8 | 735 | 24.0 | 38.4 | 14.4 | |||
110AC-1200 | 110 | 121 | 3750 | 11.0 | 88.0 | 33.0 | |||
120AC-1200 | 120 | 132 | 4550 | 9.8 | 96.0 | 36.0 | |||
220AC-1200 | 220 | 242 | 14400 | 4.2 | 176 | 66.0 |
Insulation Resistance | 1000MΩ min (at 500VDC) | Item 4.11 of IEC 61810-7 |
Dielectric Strength |
|
|
Between Contacts | 50Hz 1000V | Item 4.9 of IEC 61810-7 |
Between Contact and Coil | 50Hz 1500V | Item 4.9 of IEC 61810-7 |
Shock Resistance | 98m/s² 11ms | Item 4.26 of IEC 61810-7 |
Vibration Resistance | 10Hz~55Hz Double amplitude 1.5mm | Item 4.28 of IEC 61810-7 |
Terminals Strength | 8N 4N(PC type) | Item 4.24 of IEC 61810-7 |
Ambient Temperature | -55℃~70℃ | |
Relative Humidity | 5% to 85% | Item 4.16 of IEC 61810-7 |
Mass | 37g | Item 4.7 of IEC 61810-7 |
Note: 1). When testing, coil terminals should be connected , if LED is installed in relay
Safety approval | UL&CUR | TüV | CQC |
Load |
4C:5A/220VAC,28VDC 2C,3C:10A/220VAC,28VDC |
5A/220VAC,28VDC 7A/250VAC |
5A/220VAC;7A/250VAC |